Solution - Designer Express - Error when Commissioning a Feature Configured for Conduit Manager

Version 1

    Behavior

     

    The following error occurs when commissioning a feature that had the Existing work function set using the Express Facility Sketcher:

     

    Two errors are written to the Miner event log:

     

    2017-06-21 10:24:05,331 [1] ERROR Miner.Desktop.DesignerExpress.FeatureConverter [(null)] - Could not convert DxSurfaceStructure with OID 2803 to Feature Class Surface Structure
    {log4net:HostName=PC011F0688, log4net:UserName=G01845, LoggingAssemblyFileVersion=10.21.40.4142, log4net:Identity=}

     

    2017-06-21 10:24:05,331 [1] ERROR Miner.Desktop.DesignerExpress.FeatureConverter [(null)] - The field with model name FacilityID must be unique amongst all Surface Structure features.
    Miner.CancelEditException (0x80041006): The field with model name FacilityID must be unique amongst all Surface Structure features.
       at Miner.Framework.Autoupdaters.FacilityID.ChangeFacilityIdField(IFeature feature)
       at Miner.Framework.Autoupdaters.FacilityID.Execute(IObject pObject, mmAutoUpdaterMode eAUMode, mmEditEvent eEvent)
       at ESRI.ArcGIS.Geodatabase.IFeature.Store()
       at Miner.Desktop.DesignerExpress.FeatureConverter.ConvertFeature(FeatureConverterData featureConverterData)
       at Miner.Desktop.DesignerExpress.FeatureConverter.ConvertFeatures(List`1 featureList)
    {log4net:HostName=PC011F0688, log4net:UserName=G01845, LoggingAssemblyFileVersion=10.21.40.4142, log4net:Identity=}

     

     

    Cause

     

    This is caused by not having the FACILITYID field in the Designer Feature Class (DFC) DxSurfaceStructure that was created from the Surface Structure feature class.

     

    Solution

     

    Add the FACILITYID field to the DFC in ArcCatalog. Use the same Data Type and Field Properties as the FACILITYID field in the feature class that the DFC was derived from.