Solution - ArcFM - Unable to execute rule error in Miner event log

Version 2

    Behavior

     

    One or more of the following errors are seen in the Miner event log when Feeder Manager 1.0 is enabled but Feeder Manager 2.0 is not:

     

    Unable to execute rule: De-Energized Feature

    Unable to execute rule: Electric MultiFed Feature

    Unable to execute rule: Electric Loop Feature

     

    The following is a specific example of the Electric Loop Feature error:

     

    015-10-29 12:51:54,556 [1] ERROR Miner.Framework.QaQc.QaQcProcessor [(null)] - Unable to execute rule: Electric Loop Feature

    System.NullReferenceException: Object reference not set to an instance of an object.

     

    Cause

     

    The errors are generated by validation rules that work only with Feeder Manager 2.0. If ArcFM is configured with these validation rules checked and without Feeder Manager 2.0 enabled, the errors will be seen in the Miner event log (see Validation Rules in the ArcFM Appendix).

     

    Solution

     