Solution - Responder - Could not find feature class named Dynamic Protective Device

Version 2

    Behavior:

     

    Users may encounter an error when running the Operations on DPDs reports in Archive Explorer if the DYNAMICPROTECTICEDEVICE is given a different name.

     

    Archive Error.jpg

     

    Cause:

     

    The report configuration for these reports contains a FacilityType variable that needs to match the alias of the feature class. If the feature class is named differently than the default value, then the variables will also need to be changed.

     

     

     

    Solution

     

    The value can be changed by editing the ArchiveQueriesConfig.xml file located in the Responder\Server folder. The entry is listed a few times in the file so ensure that all variables are changed. Once the changes are saved, the Responder Windows Service needs restarted.

     

    Change Value.jpg