Solution - Object Reader - "mmUIsRes409.dll could not be found"

Version 2

    Behavior

     

    The following error is seen when using ArcCatalog (this can be a pop-up window or a Miner event log error or both):

     

    "The language library C:\Program Files (x86)\Miner and Miner\ArcFM Solution\Locales\\409\mmUlsRes409.dll could not be found in the folder C:\Program Files (x86)\Miner and Miner\ArcFM Solution\Locales\\409"

    Might also see this pop-up message "A language resource file has not been initialized for this component".

     

    Cause

     

    There is a known bug with Object Reader 10.x fixed in 10.2.1a (MM52499) & later.

     

    Solution

     

    Upgrade Object Reader to 10.2.1a higher or later. If you are unable to update simply copy a working mmUlsRes409.dll file to the specified directory. For convenience the 10.2.1 mmUlsRes409.dll is attached here as a zip file. Contact ArcFM Support to request earlier versions.