Solution - Conduit Manager - Error Message Received When Attempting to Place Lasso

Version 3

    Behavior

     

    The following error message is received when attempting to place lasso for Conduit Manager.

    Lasso Error.jpg

    (Error
    MMLassoAU.IMMSpecialAUStrategy_Execute:

    modLasso.UpdateRelationshipsForLasso
    modLasso.GetULSFeature:
    modLasso.GetFeatures
    modLasso.GetFeaturesByDistance
    Automation error #261
    Error at line: 261 - Build: 10.11.263 #226
    Error at line: 226 - Build: 10.11.263 #489
    Error at line: 489 - Build: 10.11.263 #101
    Error at line: 101 - Build: 10.11.263 #-2147220971
    Line: 89
    Error at line: 83 - Build: 10.11.263)

     

    Cause

     

     

    This error message will be given if the Lasso and Conduit feature classes exist in datasets using different coordinate systems.

     


    Solution

     

    Modify the coordinate system of the Lasso Dataset to match that of the Conduit feature class.

    Visit the ArcGIS Resource Center for information about how to modify the coordinate system for a dataset.

    ArcGIS Resources