Solution - Fiber Manager - Connection Manager Error: Input string was not in a correct format.

Version 3

    Behavior

     

    The following error message is received when attempting to open Connection Manager:

    input string not in a correct format.jpg

    (15

    Unhandled exception has occurred in a component in your

    application. If you click Continue, the application will ignore this error

    and attempt to continue.

    Input string was not in a correct format.)

    Connection Manager Red Xs.jpg

     

    Cause

     

    This error will occur if the fibercolor field is NULL for buffertube or fiberstrand objects.  This may be an indication that the Fiber Colors domain has not been assigned.

     

    Solution

     

    Make sure the Fiber Colors domain has been assigned to the fibercolor field in the buffertube and fiberstrand tables.  This will be the field assigned the FIBERCOLORFIELD model name.

     

    Visit the ArcGIS Resource Center for information on how to assign a domain to a field.