Solution - Designer - MM_WMS_DESIGN_MEMBER_TYPE -- TABLE NOT FOUND

Version 3

    Behavior

     

    The Process Framework Database Upgrade Tool reports a table not found message after executing the Workflow Manager Tables: ArcFMSystemTable Model Name task.

    designer member type.jpg

    (MM_WMS_DESIGN_MEMBER_TYPE -- TABLE NOT FOUND)

     

    Further investigation reveals that the MM_WMS_DESIGN_MEMBER_TYPE table does not exist.

     

    Cause

     

    This problem is likely related to the following bug resolved in ArcFM 10.0.1.

    MM40988:  The MM_WMS_DESIGN_MEMBER_TYPE table does not appear to get created when running the tasks to upgrade the PX Framework database to 9.3.1 SP1.

     

    Workaround

     

    No workaround is necessary because the table is not created or used.