Solution - Fiber Manager - Unhandled exception when using OTDR trace

Version 4

    Behavior

     

    The following error message is received when closing the OTDR Trace Selector Form.

    otdr unhandled exception.jpg

    (Unhandled exception
    Error: Object reference not set to an instance of an object.
    Location:  at
    Miner.FrameworkUI.FiberManager.OTDRTrace.RunTrace(IFeature feature))

     

     

    Cause

     

    This issue is related to the following bug resolved in ArcFM 10.0.3.
    MM44619:  Fiber Manager -- Closing OTDR 'Trace Selector' dialog results in Unhandled exception

     

     

    Solution

     

    Bug resolved in ArcFM 10.0.3