Solution - Conduit Manager - Unable to update conduit after adding ducts in ArcFM Conduit Configuration Dialog

Version 6

    Behavior

     

    The following error message may be received after using the ArcFM Conduit Configuration dialog.

    ConduitRelationshipForwardError.jpg

     

    (Error
    UpdateCrossSection.IMMSpecialAUStrategyEx_ExecuteUpdateCrossSection.IMMSpecialAUStrategy_Execute:
    UpdateCrossSection.ModifyRelatedCrossSections: Object variable or
    With block variable not set
    Error at line: 260 - Build: 10.10.278
    Error at line: 76 - Build: 10.10.278
    Error at line: 761 - Build: 10.10.278)


    The following error messages may also be in the Miner Event Viewer log.
    2013-04-09 16:15:17,446 [1] ERROR  [(null)] - "AutoUpdater failed: ArcFM Check Cross Section
    On Object Class: ConduitSystem
    On Event: mmEventFeatureUpdate"

    HRESULT: -2146828197
    File: "MMAutoUpdater.cpp"
    Line: 814
    {log4net:HostName=TESTVM, LoggingAssemblyFileVersion=10.10.0.276}


    2013-04-09 16:15:17,446 [1] ERROR  [(null)] - mmUlsAUs:
    UpdateCrossSection.IMMSpecialAUStrategyEx_ExecuteUpdateCrossSection.IMMSpecialAUStrategy_Execute:
    UpdateCrossSection.ModifyRelatedCrossSections: Object variable or With block variable not set
    Error at line: 260 - Build: 10.10.278
    Error at line: 76 - Build: 10.10.278
    Error at line: 761 - Build: 10.10.278
    {log4net:HostName=TESTVM, LoggingAssemblyFileVersion=10.10.0.276}


    2013-04-09 16:15:17,446 [1] ERROR  [(null)] - mmUlsAUs:
    UpdateCrossSection.IMMSpecialAUStrategy_Execute: UpdateCrossSection.ModifyRelatedCrossSections: Object variable or With block variable not set
    Error at line: 260 - Build: 10.10.278
    Error at line: 76 - Build: 10.10.278
    {log4net:HostName=TESTVM, LoggingAssemblyFileVersion=10.10.0.276}


    2013-04-09 16:15:17,430 [1] ERROR  [(null)] - mmUlsAUs:
    UpdateCrossSection.ModifyRelatedCrossSections: Object variable or With block variable not set
    Error at line: 260 - Build: 10.10.278
    {log4net:HostName=TESTVM, LoggingAssemblyFileVersion=10.10.0.276}

     

    Cause

     

    This error message will be given if the Conduit_CrossSectionAnnotation relationship is using Forward notification instead of None.

    Solution

     

    Recreate the Conduit_CrossSectionAnnotation relationship and select None for the Notification type.

    Visit the ArcFM Solution Resource Center for information about how to configure Conduit Manager.