Solution - Designer - Blank CU Tab After Upgrade to 9.3.1

Version 3

    Behavior

     

    The CU tab is empty after a design has been opened for editing and there are no work functions available for selection.
    The problem was introduced after an upgrade to ArcFM 9.3.1 or 9.3.1 SP1.

    workfunction.jpg

     

    Cause

     

    This problem will occur if there are duplicate descriptions in the MM Work Function domain.
    This behavior may be related to a bug introduced in the ArcFM 9.3.1 installation and resolved in ArcFM 10.0.1.  The problem occurs because of a new coded value added to the MM Work Function domain during the upgrade to ArcFM 9.3.1.

     

    Workaround

     

    Modify the MM Work Function domain and change the duplicate description.

    1. Launch ArcCatalog and connect to the geodatabase as the owner of the MM Work Function domain.
    2. Right-click the geodatabase and click Properties.
    3. Click the Domains tab.
    4. Select the MM Work Function domain.
    5. Update the duplicate coded value description to be a unique value.