Solution - Fiber Manager - Device ports not available in Connection Manager

Version 2

    Behavior

     

    When a device has been added to a rack, the device ports may not be available in Connection Manager.

     

    Cause

     

    This will occur if the Rack object has not been configured to be a parent to multiple child objects.

     

    Solution

     

    Configure the Rack object to be parent to multiple objects:

    1. Launch ArcCatalog and connect to the geodatabase.
    2. Right-click the Rack object and select ArcFM Properties Manager.
    3. Click the Model Names tab and add the FIBERMULTICONTAINER model name.
    4. Apply the changes and click OK.
    5. Right-click the Rack object and select Properties.
    6. Click the Fields tab and select the FIBERCHILDCLASSMODELNAME.
    7. Make sure a default value is not assigned.