FAQ - ArcFM - Feature Fields used by Feeder Manager 1.0 and 2.0

Version 4

    Question

     

    Which fields in electric features are updated and used by Feeder Manager 1.0 and 2.0?

     

    Answer

     

    Feeder Manager efficiently manages circuit power sources and phasing. It does this by populating various fields of circuit features that are correlated. Numerous fields used by Feeder Manager 1.0 and Feeder Manager 2.0 are different, which is of primary interest to administrators who write scripts or autoupdaters that monitor information from these fields.

     

    Feeder Manager 1.0 fields (deprecated for Feeder Manager 2.0):

    FeederID
    FeederID2
    FeederInfo
    ParentCircuitSourceID

     

    Feeder Manager 2.0 fields

    FeederIDs
    Subfeeder IDs
    Energized Phases
    Number of Feeders
    Loop 
    Tie device

     

    The Feeder Sync Tool allows users to populate Feeder Manager 1.0 fields using data from Feeder Manager 2.0 fields. The following topic has more details: Feeder Sync